No.
|
Items
|
Function/Features
|
Installation location
|
Person in charge of operations
|
|
1
|
Dust Track, 8532 Dust Track
Origin: USA
|
Measuring Total Dust, PM.10, PM.2,
|
Room 516, B2 Building, 18 Hoang Quoc Viet street, Phu Dien, Ha Noi
|
BSc. Le Quang Vinh
|
|
2
|
Pocket Weather tracker 4000
Origin: USA
|
Measuring microclimate on site (temperature, humidity, wind speed).
|
Room 516, B2 Building, 18 Hoang Quoc Viet street, Phu Dien, Ha Noi
|
BSc. Le Quang Vinh
|
|
3
|
Air sampling pump, 224-PCXR8KD, SKC
|
- Air sampling pump flow: 5-5000 ml / min.
- Automatic sampling function according to the program set in 7 days
The device has the ability to automatically stop when the battery is low.
|
Room 516, B2 Building, 18 Hoang Quoc Viet street, Phu Dien, Ha Noi
|
BSc. Le Quang Vinh
|
|
4
|
Vibration meter 3 M
Origin: USA
|
Measuring vibration
|
Room 516, B2 Building, 18 Hoang Quoc Viet street, Phu Dien, Ha Noi
|
MSc. Nguyen Duc Nui
|
|
5
|
Portable Particulate Air Sampler
Dust - Sol DS-2.5
Origin: USA
|
- 10,000 continuous hour diaphragm pump.
- Variable flow adjustment 0-6 LPM
|
Room 516, B2 Building, 18 Hoang Quoc Viet street, Phu Dien, Ha Noi
|
BSc. Le Quang Vinh
|
|
6
|
Multiparameter Meter, U-52G, Horiba
Origin: Japan
|
11 parameters (Temp., pH, DO, ORP, TDS, Conductivity, Turbidity, Salinity, Seawater Specific Gravity, etc) can be measured and displayed at the same time
|
Room 516, B2 Building, 18 Hoang Quoc Viet street, Phu Dien, Ha Noi
|
BSc. Le Quang Vinh
|
|
7
|
Radiation Alert Range, Se-International
Origin: USA
|
- Operating Range: 0,001- 0 mR/hr; 0 - 300,000 CPM; 0 - 9,999,000 Total Counts; 01- 1,000 mSv/hr
|
Room 516, B2 Building, 18 Hoang Quoc Viet street, Phu Dien, Ha Noi
|
Dr. Phan Van Truong
|
|
8
|
Benchtop pH Meter
|
Measuring range 0 - 14
|
Room 516, B2 Building, 18 Hoang Quoc Viet street, Phu Dien, Ha Noi
|
BSc. Lê Quang Vinh
|
|
9
|
GPS device (Global Positioning System device)
Origin: USA
|
- Time (RTCM): 2 – 4 m
- Time (Advanced GPS, SBAS1, WAAS or EGNOS): 1 – 2 m
No. channel: 50 (only with L1)
Integrated real-time clock: RTCM v2.3
Update rate: 1 Hz
Protocol: NMEA-0183, binary UBX, MCX port for optional external GPS antenna
Memory: 8 GB (5B), 16 GB (5D), or 32 GB (5B/5D with barcode scanner, Advanced GPS) built-in memory, and 512 MB RAM
|
Room 516, B2 Building, 18 Hoang Quoc Viet street, Phu Dien, Ha Noi
|
MSc. Nguyen Duc Nui
|
|
10
|
High-temperature flue gas concentration measuring device (Einstruments E9000)
Origin: USA
|
- Advanced Gas Sensing: Supports up to 9 sensors, including 𝑂2, 𝐶𝑂, 𝑁𝑂, 𝑁𝑂2, 𝑆𝑂2, 𝐻2𝑆 (electrochemical) and CO2, CxHy.
- High-Temperature Capability: Includes heated sample line and probe head, with options for probes handling up to 2190∘F (1200∘C)
- Measurement Precision: Offers Low
NOx and True NOx capabilities.
- Data and Connectivity: Includes internal memory (16,000 tests), a built-in printer, USB, Bluetooth, and an Android app for data management.
- Durability: Supplied in a heavy-duty aluminum carrying case for transportable, field-based testing.
- Automatic Conditioning: Features an internal thermoelectric chiller with automatic condensate removal to ensure accurate measurements.
|
Room 516, B2 Building, 18 Hoang Quoc Viet street, Phu Dien, Ha Noi
|
MSc. Nguyen Duc Nui
|
|
11
|
Dust Sample (model DS-2.5)
Origin: USA
|
Weight: 14.0 lbs (6.3kg)
Standard filter 47mm
Power supply: AC/DC, with low battery indicator
Programmable 7-day, 24-hour counter
Diaphragm pump: 10.000 hours
Adjust flow: 0-6 LPM
Weather resistant.
|
Room 516, B2 Building, 18 Hoang Quoc Viet street, Phu Dien, Ha Noi
|
Dr. Phan Van Truong
|
|
12
|
Gas sampling device (SCK 224-PCXR8KD)
Origin: USA
|
- Flow Rate Range: 5 to 5000 ml/min (0.005 to 5 LPM), suitable for both low-flow and high-flow sampling.
- Intrinsically Safe: Certified to UL standards for Class I, Division 1 and 2 (Groups A, B, C, D), Class II (Groups E, F, G), and Class III, suitable for hazardous environments.
- Programmability: Features a built-in timer, allowing for automatic sampling schedules, delayed start, and up to 9999 minutes of operation.
- Accuracy: Maintains a constant flow with ±5% accuracy of the set point.
- Battery and Runtime: Uses a rechargeable 6V NiMH battery, offering an extended runtime of over 12 hours at 4 LPM.
- Robust Construction: Features a durable, electromagnetic interference (EMI)-resistant housing.
- Portability: Compact design with a built-in flow meter (with markers at 1, 2, 3, 4, and 5 LPM) for quick, on-site checks.
Applications: Ideal for collecting, gas, vapor, and particulate samples (e.g., using cyclone for respirable dust
|
Room 516, B2 Building, 18 Hoang Quoc Viet street, Phu Dien, Ha Noi
|
Dr. Phan Van Truong
|
|
13
|
COD digestion device
Origin: Germany
|
COD digestion device has 8 holes
Temperature has 5 different temperature modes: 70, 100, 120, 150, 160oC
Working time: 30 minutes, 60 minutes, 120 minutes or continuous.
Safety Features: High-quality design with protective covers and automatic safety shutdown to prevent overheating.
|
Room 502, B2 Building, 18 Hoang Quoc Viet street, Phu Dien, Ha Noi
|
MSc. Le Thi Hai Ninh
|
|
14
|
Aquatron Water Still (AQUATRON A4000D)
Origin: USA
|
· Water source: Tap water
· Water pressure: 1.0–5.0 kg/cm² (0.0981–0.4905 MPa)
· Water temperature: 5–45 °C
· TDS: < 200 ppm
· Inlet flow rate: 1.0–2.0 L/min
· Power supply: 220 V, 50 Hz, 50–80 W
|
Room 502, B2 Building, 18 Hoang Quoc Viet street, Phu Dien, Ha Noi
|
Dr. Pham Thi Hai Thinh
|
|
15
|
Digital Ultrasonic Cleaner-set (WUC-D06H)
Origin: Korea
|
· Ultrasonic frequency: 40,000 Hz
· Tank capacity: 10 L
· Timer setting: 1–99 min
· Ultrasonic power: up to 240 W, adjustable
· Heating power: 500 W
· Ultrasonic power setting: 10–100%
· Maximum temperature setting: 60 °C
|
Room 502, B2 Building, 18 Hoang Quoc Viet street, Phu Dien, Ha Noi
|
MSc. Nguyen Duc Nui
|
|
16
|
The Dionex Integrion HPIC system (Dionex Intergrion)
Origin: USA
|
With the capability to analyze a wide variety of sample matrices and a broad concentration range of target analytes (from trace levels—ppb, ppm—to major constituents), ion chromatography offers high accuracy and selectivity. In addition, this technique requires minimal use of organic solvents and hazardous chemicals, thereby reducing adverse environmental impacts.
Analysis of cations (Li⁺, Na⁺, NH₄⁺, K⁺, Ca²⁺, Mg²⁺) in water and wastewater samples is performed in accordance with TCVN 6660:2000 and ISO 14911:1998, using ion chromatography equipped with a conductivity detector. A cation-exchange column is employed with methanesulfonic acid as the mobile phase, together with a cation suppressor.
Analysis of anions: F⁻, Cl⁻, NO₂⁻, NO₃⁻, Br⁻, SO₄²⁻, PO₄³⁻.
Included accessories and components:
1. Pump (dual serial piston pump)
- Pump head and tubing made of PEEK polymer, metal-free; compatible with a pH range of 0–14 and solvents such as methanol and acetonitrile
- Flow rate range: up to 10 mL/min
- Flow rate precision: < ±0.1%
- Flow rate accuracy: < ±0.1%
- Operating pressure: 0–41 MPa (0–6000 psi)
- Pressure ripple: < 1% at 1 mL/min
2. Conductivity detector
- Digital signal processor
- Cell frequency: 8 kHz
- Signal filtering: adjustable data filtering time from 0 to 10 s
- Resolution: 0.00238 nS/cm
- Linearity: 1%
- Maximum cell pressure: 10 MPa (1500 psi)
3. Column compartment
- Six-port injection valve
- Temperature range: 30–80 °C
- Temperature stability: ±0.2 °C
- Temperature accuracy: ±0.5 °C
- Leak detection sensor
|
Room 209, B2 Building, 18 Hoang Quoc Viet street, Phu Dien, Ha Noi
|
Dr. Pham Thi Hai Thinh
|
|
17
|
Nitrogen Distillation System
Origin: Italia
|
· The instrument is designed for the determination of ammonia, nitrogen, protein (Kjeldahl method), nitrate (after reduction), phenol, volatile acids, cyanide, alcohol content, sulfur dioxide, TVBN, and nitrogen (Devarda method).
· The steam generator operates without pressurized flow, ensuring safe distillation, eliminating heating delay time, and requiring no maintenance.
· The condenser, manufactured from titanium, reduces water consumption and ensures that the condensation temperature always remains below the theoretical value.
· Devarda analysis time: 0–99 min.
· Number of operating programs: 10 programs.
· Measurement repeatability (RSD): ≤ 1%.
· Recovery: ≥ 99.5% for nitrogen concentrations ranging from 1 to 200 mg.
· Limit of detection: ≥ 0.1 mg N.
· Power consumption: 2100 W.
· Power supply: 220 V, 50 Hz.
· Distillation time for 100 mL: 4 min.
· NaOH (alkali) addition: automatic.
· Distilled water addition: automatic.
· NaOH (alkali) addition volume: 0–100 mL.
· Distilled water addition volume: 0–200 mL.
· Distillation time: programmable.
· Distillate waste aspiration: automatic.
· Steam flow adjustment: 10–100%.
· Cooling water consumption: 0.5 L/min at 15 °C, or 1 L/min at 30 °C.
|
Room 502, B2 Building, 18 Hoang Quoc Viet street, Phu Dien, Ha Noi
|
MSc. Le Thi Hai Ninh
|
|
18
|
Expanded Granular Sludge Bed (EGSB) reactor
|
Total volume 15.0 dm3. This equipment is capable of treating wastewater with high organic matter content. Stable treatment efficiency about 90% at an OLR of about 15 kg COD/m3.day
|
Room 115, B2 Building, 18 Hoang Quoc Viet street, Phu Dien, Ha Noi
|
Dr. Duong Van Nam
|
|
19
|
Modified Sequencing Batch Reactor (SBR)
|
Total volume 15.0 dm3. This equipment is capable of simultaneously removal of organic and nitrogen matter in wastewater. COD, ammonium and TN removal efficiency is 97%, close to 100% and 94 - 97%, in COD and TN loading rates in the range of 0.9 - 1.6 kg COD/m3.day, and 16 – 0.31 kg N/ m3.day, respectively.
|
Room 115, B2 Building, 18 Hoang Quoc Viet street, Phu Dien, Ha Noi
|
Dr. Duong Van Nam
|